Electric Blower Heaters
Product Overview

Print this page

Dexon Electric Blower Heaters provide positive air pressure ventilation (where tempered air is required) to equipment or storage vaults, pumping stations, or other confined spaces where a safer, dryer, less corrosive environment is desired for equipment and operator safety. They will maintain an adjustable preset discharge temperature. Large units 6 kw. and up have staged heating elements to minimize power supply and demand billing charges.

Blower Heaters are easy to install, simply mount unit to structure, then run appropriate conduit for power, remote status and optional features used, run power to unit and make adjustments, if required to fan speed. For easy servicing of units the controls, elements and in most cases the blowers are mounted on a single removable panel.

All Blower Heaters are CSA Certified or Approved for ordinary Location or for Class 1, Div. 2, Group C & D Locations. Outdoor freestanding units are certified or approved for Enclosure Type 3R.

IMPORTANT:

CSA Certification or Approval for Ordinary Location is identified by a -1 at the end of the model number. If a -1 is not present the unit will be CSA Certified for Class 1 Div.2 Locations.


Examples:
MDH3 -1 would be for ordinary location
MDH3 would be for Class 1, Div.2 location

MDH Series Blower Heater
  • Free Standing units with 360° louver section
  • 2000 to 4500 watts, single staged elements
  • Available in 120, 208, 240, 480 or 600 VAC, 1 or 3 phase (except for 120V)
  • 80 - 300CFM @ 0 inches Static Pressure Water Column
  • Variable speed brushless DC blower

MDHIL Series Blower Heater
  • Indoor In-line units with top or side inlet collars
  • 2000 to 4500 watts, single staged elements
  • Available in 120, 208, 240, 480 or 600 VAC, 1 or 3 phase (except for 120V)
  • 80 - 300CFM @ 0 inches Static Pressure Water Column
  • Variable speed brushless DC blower

SMDH Series
  • Free Standing units with louvers on one side only
  • " 2000 to 25500 watts. One, two or three staged elements
  • " Available in 120, 208, 240, 480 or 600 VAC, 1 or 3 phase (except for 120V)
  • 80 - 3000 CFM with single blower @ 0 inches Static Pressure Water Column
  • 80 - 6000 CFM with dual blowers @ 0 inches Static Pressure Water Column
  • " Variable speed brushless DC blower(s)

WMDH Series
  • Indoor wall mount units with separate louver section
  • 2000 to 25500 watts. One, two or three staged elements
  • Available in 120, 208, 240, 480 or 600 VAC, 1 or 3 phase (except for 120V)
  • 80 - 3000 CFM with single blower @ 0 inches Static Pressure Water Column
  • 80 - 6000 CFM with double blowers @ 0 inches Static Pressure Water Column
  • Variable speed brushless DC blower(s)

IMDH Series
  • Indoor In-line mount units with inlet collar for ducting
  • 2000 to 25500 watts. One, two or three staged elements
  • Available in 120, 208, 240, 480 or 600 VAC, 1 or 3 phase (except for 120V)
  • 80 - 3000 CFM with single blower @ 0 inches Static Pressure Water Column
  • 80 - 6000 CFM with double blowers @ 0 inches Static Pressure Water Column
  • Variable speed brushless DC blower(s)

All Dexon Electric Blower Heaters are available in one or three phase, and required power supply voltages of 120/208,120/240,120/480, or 120/600.

WARNING: These units are designed to run continuously. Failure to do so may void warranty. Dexon will not be liable for any personal injuries, equipment or property damage caused by inappropriate installation or operations.

Please note: The airflow capacities listed above are only a guideline of the range of these products. Proper sizing is required to match air flow, versus heating capacities with regards to local climatic conditions, external system pressures, etc.. Please contact Dexon to facilitate sizing.