Features
The Dexon Clean Air Handling System uses a fully variable blower and pumps, and a hydronic coil to provide a continuous gentle airflow throughout your home maintaining a constant even temperature. Depending on the package and options chosen, the Dexon Clean Air Handling System will provide:
- Heating using various heat sources such as Geothermal System, highly efficient Condensing Boilers, Solar, etc.
- Power Cooling with Geothermal System or Power Chiller. A single combination (heating/cooling) combo coil is used for both the cooling and the heating.
- Power Cooling with Conventional Air Conditioner. An A-Frame coil can be attached to the Supply Air using a Vertical Configuration, or a Coil Module and DX Coil can be added to the Air Handle using a Horizontal Configuration.
- Fully variable blower that automatically proportionately adjusts speed to meet the varying needs of heating, cooling and air quality control.
- Fully variable speed pump that automatically proportionately adjusts speed to meet demands.
- Built-in Exhaust interlock for range hoods, Jen Air, etc.
- Monitored and automatically controlled Return Air and Outside Air Intake dampers for econo cooling and/or air quality control.
- Econo cooling - Automatic damper control to utilize cooler outdoor air for cooling.
- Air quality monitoring and automatic damper control to maintain optimum air quality.
- Various Filtration Options UV/Photocatilytic, HEPA up to 99.997% @ 0.12 micron or activated carbon
- Temperature Differential Zone Control uses a full port zone duct splitter to further maintain even temperature in different locations in your home, for example the top floor versus the main, or North side versus South.
Benefits
- Energy savings:
- By using a highly efficient condensing boiler or GEO System you reduce energy costs and the same energy efficient heat source can be used for other things, like Domestic Hot Water, Radiant Floor or Fin type heating, Hot Tubs and Swimming Pools.
- The Air Handler blower, controls and pumps require minimal electricity, approximate equivalent to 3 100watt light bulbs.
- Health and Comfort:
- The constant low airflow eliminates the cold drafts of the conventional start and stop furnaces.
- The System provides the best air quality by monitoring the quality of the inside air versus the quality of the outside air and adjusting the dampers to supply optimum indoor air quality.
- Has provisions to accommodate three different types of air filtration, HEPA, UV/Photocatalytic, Activated Carbons.
- Econo Cool Feature provides some cooling without Conventional Air Conditioning.
- Flexibility:
- Has different packages for wide range of heating and cooling options.
- Offers 3 different filtration options that can be added at any time (HEPA requires high pressure blower).
- Vertical or Horizontal Configurations.
- Integrated Controls:
- The Control Center interfaces with different components required to have a complete working system.
- Simplifies onsite installation and reduces potential for errors.
- Ensures component compatibility
- Up Front Installation savings:
- The Return Air Module and the Outside Air Modules come already equipped with full port dampers.
- Exhaust interlock interface is built into the system.
- Econo cool feature is also built into the system.
- The Air Handler is HEPA, UV/Photocatalytic or carbon ready
- Pre-connected junction boxes are provided for damper actuator and transfer valves saving time and reducing potential errors.
System Overview
The main components of the Dexon Clean Air Handling System are the Control Centre and the Air-Handler.
The Control Centre interfaces with the various heating and cooling sources, pumps, temperature sensors and monitors to efficiently maintain the pre-set parameters of the system. Depending on the options chosen the system can be fully automatic or can allow for some owner intervention.
The Air Handler provides the fully variable airflow, the coils for heating and cooling and the various air filtration options.
- It is modular in design so that it can easily fit through regular doors and consists of a minimum of 4 modules.
- Module 1 which can be used for either the Return Air or Outside Air Intake depending on installation requires.
- Module 2 can also be used for either the Return Air or Outside Air Intake
- Module 3 houses the blower and controls
- Module 4 houses the coil and provisions for optional filtration.
- Is dual skinned and fully insulated to prevent thermal bridging with no foil back insulation in the air stream.
- All modules are powder-coated wrinkle black inside and out to prevent off gassing with attractive Stainless Steel Hoods.
- Gasket between modules, as well as tight fitting filters, ensures that the maximum amount of air passes through air filters rather than around them.
- Controlled Return Air and Outside Air Intake dampers can provide up to 100% outside air in that would also pass through the various filter options.
- Both Return air and Outside Air Intake modules are equipped with special prefilters, made of patented blend of activated carbons on a GM6.0, Merv 7 particulate media.
Air Handler is available in vertical or horizontally configuration
Packages
The Dexon Clean Air Handling System is available in 5 Package Options, 6 Option Features and 2 Air-Handler sizes.
Package A With GEO, With Qualtrol controller
This package uses a Geothermal Heat Pump as a Heating and Power Cooling source. The Dexon Qualtrol controller and Air Quality Monitors automate the return air and outside air intake dampers for air quality control, Econo Cool Feature and Exhaust Interlock.
Package B With GEO, Without Qualtrol Controller
This package uses Geothermal Heat Pump as a heating and Power Cooling source. Has return air and outside air intake damper control for Econo Cool Feature and Exhaust Interlock but no air quality monitoring.
Package C - 1 to C - 4 Without GEO, With Qualtrol Controller
This package uses alternate heating sources such as boilers, or solar etc. for heating and the following cooling options.
- C-1 Power Chiller Cooling
- C-2 Conventional Air conditioning with Evaporating DX Coil
- C-3 Conventional Air conditioning with A-Frame Coil
- C-4 No Power Cooling
Dexon Qualtrol controller and Air Quality Monitors automate the return air and outside air intake dampers for air quality control, Econo Cool Feature and Exhaust Interlock.
Package D-1 TO D- 4 Without GEO, Without Qualtrol Controller
This package uses alternate heat sources such as boilers, or solar etc. for heating and the following cooling options.
- D-1 Power Chiller Cooling
- D-2 Conventional Air conditioning with Evaporating DX Coil
- D-3 Conventional Air conditioning with A-Frame Coil
- D-4 No Power Cooling
Package E Basic Unit
This package uses alternate heat sources such as boilers, or solar etc and no power cooling option. The outside air intake damper is manually operated and the return air damper is automated for exhaust interlock.
Optional Features
Temperature Differential Zone Control An option that uses the Dexon T-Diff Controller to adjust a Dexon Full Port Zone Duct Splitter that will direct more or less conditioned air to different areas of your home (North/South, Upstairs/Downstairs etc.), based on demand.
GEO Buffer Tank Loop Pump on Demand An energy saving device that will turn the GEO Buffer Tank Loop Pump - PM2 on or off based on demand when there are no load demands on the loop.
GEO Open Well Loop Water Flow Verification (WLWFV) - Verifies that there is adequate water flow from the well before the compressor starts, thus preventing freeze-up of the GEO system coil.
HEPA Air Filtration - Filters particulates from the supply air flow at efficiency from 99.95% @ 0.3 micron to 99.995% @ 0.12 micron.
UV/Photocatalytic Air Filtration Will reduce the levels of bacteria, viruses, molds, smoke and VOCs in your home.
Carbon Filtration Adsorbs odours using activated carbon.
Sizes
The Air Handler is available in 2 sizes, each can be mounted vertically or horizontally, and each can have a low-pressure blower or high-pressure blower. Model numbers are as follows.
Larger unit: 76.5 x 65.5 CM
Smaller unit: 61.5 x 52.0 CM